FIX: replace ',' with '.' when using minor languages
Change-Id: I992f4c702141f89860625f64d9524ee1c0445cee
This commit is contained in:
parent
e1178d122a
commit
21abdb24da
|
@ -5,13 +5,6 @@
|
|||
#include "libslic3r/Print.hpp"
|
||||
|
||||
namespace Slic3r { namespace GUI {
|
||||
std::string float_to_string(float value, int precision = 2)
|
||||
{
|
||||
std::stringstream stream;
|
||||
stream << std::fixed << std::setprecision(precision) << value;
|
||||
return stream.str();
|
||||
}
|
||||
|
||||
CaliPresetCaliStagePanel::CaliPresetCaliStagePanel(
|
||||
wxWindow* parent,
|
||||
wxWindowID id,
|
||||
|
|
|
@ -2034,6 +2034,8 @@ int MachineObject::command_start_calibration(bool vibration, bool bed_leveling,
|
|||
|
||||
int MachineObject::command_start_pa_calibration(const X1CCalibInfos &pa_data, int mode)
|
||||
{
|
||||
CNumericLocalesSetter locales_setter;
|
||||
|
||||
pa_calib_results.clear();
|
||||
if (get_printer_series() == PrinterSeries::SERIES_X1) {
|
||||
json j;
|
||||
|
@ -2078,7 +2080,7 @@ int MachineObject::command_set_pa_calibration(const std::vector<PACalibResult> &
|
|||
j["print"]["filaments"][i]["name"] = pa_calib_values[i].name;
|
||||
j["print"]["filaments"][i]["k_value"] = std::to_string(pa_calib_values[i].k_value);
|
||||
if (is_auto_cali)
|
||||
j["print"]["filaments"][i]["n_coef"] = std::to_string(pa_calib_values[i].n_coef);
|
||||
j["print"]["filaments"][i]["n_coef"] = std::to_string(pa_calib_values[i].n_coef);
|
||||
else
|
||||
j["print"]["filaments"][i]["n_coef"] = "0.0";
|
||||
}
|
||||
|
@ -2156,6 +2158,8 @@ int MachineObject::commnad_select_pa_calibration(const PACalibIndexInfo& pa_cali
|
|||
|
||||
int MachineObject::command_start_flow_ratio_calibration(const X1CCalibInfos& calib_data)
|
||||
{
|
||||
CNumericLocalesSetter locales_setter;
|
||||
|
||||
if (get_printer_series() == PrinterSeries::SERIES_X1 && calib_data.calib_datas.size() > 0) {
|
||||
json j;
|
||||
j["print"]["command"] = "flowrate_cali";
|
||||
|
|
|
@ -984,6 +984,18 @@ void CalibUtils::send_to_print(const CalibInfo &calib_info, std::string &error_m
|
|||
print_job->set_print_config(MachineBedTypeString[bed_type], true, false, false, false, true);
|
||||
print_job->set_print_job_finished_event(wxGetApp().plater()->get_send_calibration_finished_event(), print_job->m_project_name);
|
||||
|
||||
{ // record the print job
|
||||
json j;
|
||||
j["print"]["cali_type"] = calib_info.params.mode;
|
||||
j["print"]["flow_ratio_mode"] = flow_ratio_mode;
|
||||
j["print"]["tray_id"] = calib_info.select_ams;
|
||||
j["print"]["dev_id"] = calib_info.dev_id;
|
||||
j["print"]["start"] = calib_info.params.start;
|
||||
j["print"]["end"] = calib_info.params.end;
|
||||
j["print"]["step"] = calib_info.params.step;
|
||||
BOOST_LOG_TRIVIAL(trace) << "send_cali_job: " << j.dump();
|
||||
}
|
||||
|
||||
print_job->start();
|
||||
}
|
||||
|
||||
|
|