FIX: the n value is not correct when set pa cali value
If it is manual, set it to 0, if it is automatic, use the calibrated value Change-Id: I7c8737366e0ec0c6c2c17a7ad905cfb34e236fd8 (cherry picked from commit b235b0c8b79b1baf6a393ccfea236e1e650dcb7d)
This commit is contained in:
parent
c5ea3c8b71
commit
3d52954374
|
@ -295,7 +295,7 @@ void HistoryWindow::sync_history_data() {
|
|||
name_value->SetLabel(from_u8(new_result.name));
|
||||
|
||||
new_result.tray_id = -1;
|
||||
CalibUtils::set_PA_calib_result({ new_result });
|
||||
CalibUtils::set_PA_calib_result({ new_result }, true);
|
||||
|
||||
enbale_action_buttons(false);
|
||||
}
|
||||
|
|
|
@ -593,7 +593,7 @@ void PressureAdvanceWizard::on_cali_save()
|
|||
return;
|
||||
}
|
||||
|
||||
CalibUtils::set_PA_calib_result(new_pa_cali_results);
|
||||
CalibUtils::set_PA_calib_result(new_pa_cali_results, true);
|
||||
}
|
||||
else if (m_cali_method == CalibrationMethod::CALI_METHOD_MANUAL) {
|
||||
PACalibResult new_pa_cali_result;
|
||||
|
@ -601,7 +601,7 @@ void PressureAdvanceWizard::on_cali_save()
|
|||
if (!save_page->get_manual_result(new_pa_cali_result)) {
|
||||
return;
|
||||
}
|
||||
CalibUtils::set_PA_calib_result({ new_pa_cali_result });
|
||||
CalibUtils::set_PA_calib_result({ new_pa_cali_result }, false);
|
||||
}
|
||||
|
||||
MessageDialog msg_dlg(nullptr, _L("Flow Dynamics Calibration result has been saved to the printer"), wxEmptyString, wxOK);
|
||||
|
|
|
@ -2036,7 +2036,7 @@ int MachineObject::command_start_pa_calibration(const X1CCalibInfos &pa_data, in
|
|||
return -1;
|
||||
}
|
||||
|
||||
int MachineObject::command_set_pa_calibration(const std::vector<PACalibResult>& pa_calib_values)
|
||||
int MachineObject::command_set_pa_calibration(const std::vector<PACalibResult> &pa_calib_values, bool is_auto_cali)
|
||||
{
|
||||
CNumericLocalesSetter locales_setter;
|
||||
|
||||
|
@ -2056,8 +2056,10 @@ int MachineObject::command_set_pa_calibration(const std::vector<PACalibResult>&
|
|||
j["print"]["filaments"][i]["setting_id"] = pa_calib_values[i].setting_id;
|
||||
j["print"]["filaments"][i]["name"] = pa_calib_values[i].name;
|
||||
j["print"]["filaments"][i]["k_value"] = std::to_string(pa_calib_values[i].k_value);
|
||||
// j["print"]["filaments"][i]["n_coef"] = std::to_string(pa_calib_values[i].n_coef);
|
||||
j["print"]["filaments"][i]["n_coef"] = "0.0";
|
||||
if (is_auto_cali)
|
||||
j["print"]["filaments"][i]["n_coef"] = std::to_string(pa_calib_values[i].n_coef);
|
||||
else
|
||||
j["print"]["filaments"][i]["n_coef"] = "0.0";
|
||||
}
|
||||
|
||||
BOOST_LOG_TRIVIAL(trace) << "extrusion_cali_set: " << j.dump();
|
||||
|
|
|
@ -818,7 +818,7 @@ public:
|
|||
|
||||
// PA calibration
|
||||
int command_start_pa_calibration(const X1CCalibInfos& pa_data, int mode = 0); // 0: automatic mode; 1: manual mode. default: automatic mode
|
||||
int command_set_pa_calibration(const std::vector<PACalibResult>& pa_calib_values);
|
||||
int command_set_pa_calibration(const std::vector<PACalibResult>& pa_calib_values, bool is_auto_cali);
|
||||
int command_delete_pa_calibration(const PACalibIndexInfo& pa_calib);
|
||||
int command_get_pa_calibration_tab(float nozzle_diameter, const std::string &filament_id = "");
|
||||
int command_get_pa_calibration_result(float nozzle_diameter);
|
||||
|
|
|
@ -265,7 +265,7 @@ bool CalibUtils::get_PA_calib_info(PACalibResult & pa_calib_info) {
|
|||
return false;
|
||||
}
|
||||
|
||||
void CalibUtils::set_PA_calib_result(const std::vector<PACalibResult>& pa_calib_values)
|
||||
void CalibUtils::set_PA_calib_result(const std::vector<PACalibResult> &pa_calib_values, bool is_auto_cali)
|
||||
{
|
||||
DeviceManager* dev = Slic3r::GUI::wxGetApp().getDeviceManager();
|
||||
if (!dev)
|
||||
|
@ -275,7 +275,7 @@ void CalibUtils::set_PA_calib_result(const std::vector<PACalibResult>& pa_calib_
|
|||
if (obj_ == nullptr)
|
||||
return;
|
||||
|
||||
obj_->command_set_pa_calibration(pa_calib_values);
|
||||
obj_->command_set_pa_calibration(pa_calib_values, is_auto_cali);
|
||||
}
|
||||
|
||||
void CalibUtils::select_PA_calib_result(const PACalibIndexInfo& pa_calib_info)
|
||||
|
|
|
@ -41,7 +41,7 @@ public:
|
|||
static void emit_get_PA_calib_info(float nozzle_diameter, const std::string &filament_id);
|
||||
static bool get_PA_calib_info(PACalibResult &pa_calib_info);
|
||||
|
||||
static void set_PA_calib_result(const std::vector<PACalibResult>& pa_calib_values);
|
||||
static void set_PA_calib_result(const std::vector<PACalibResult>& pa_calib_values, bool is_auto_cali);
|
||||
static void select_PA_calib_result(const PACalibIndexInfo &pa_calib_info);
|
||||
static void delete_PA_calib_result(const PACalibIndexInfo &pa_calib_info);
|
||||
|
||||
|
|
Loading…
Reference in New Issue