FIX: modify the cali mode name
Change-Id: Ic234ac3ac776e40fadcf4d3a65c511ceb3946666 (cherry picked from commit 91fee384ddf055a6689160c64fdbdcc5caf91325)
This commit is contained in:
parent
04bfe7e405
commit
e9f3ddb61b
|
@ -1946,7 +1946,7 @@ int MachineObject::command_start_calibration(bool vibration, bool bed_leveling,
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
|
|
||||||
int MachineObject::command_start_pa_calibration(const X1CCalibInfos &pa_data, bool is_manual)
|
int MachineObject::command_start_pa_calibration(const X1CCalibInfos &pa_data, int mode)
|
||||||
{
|
{
|
||||||
pa_calib_results.clear();
|
pa_calib_results.clear();
|
||||||
if ((printer_type == "BL-P001" || printer_type == "BL-P002")) {
|
if ((printer_type == "BL-P001" || printer_type == "BL-P002")) {
|
||||||
|
@ -1954,7 +1954,7 @@ int MachineObject::command_start_pa_calibration(const X1CCalibInfos &pa_data, bo
|
||||||
j["print"]["command"] = "extrusion_cali";
|
j["print"]["command"] = "extrusion_cali";
|
||||||
j["print"]["sequence_id"] = std::to_string(MachineObject::m_sequence_id++);
|
j["print"]["sequence_id"] = std::to_string(MachineObject::m_sequence_id++);
|
||||||
j["print"]["nozzle_diameter"] = to_string_nozzle_diameter(pa_data.calib_datas[0].nozzle_diameter);
|
j["print"]["nozzle_diameter"] = to_string_nozzle_diameter(pa_data.calib_datas[0].nozzle_diameter);
|
||||||
j["print"]["manual"] = is_manual;
|
j["print"]["mode"] = mode;
|
||||||
|
|
||||||
for (int i = 0; i < pa_data.calib_datas.size(); ++i) {
|
for (int i = 0; i < pa_data.calib_datas.size(); ++i) {
|
||||||
j["print"]["filaments"][i]["tray_id"] = pa_data.calib_datas[i].tray_id;
|
j["print"]["filaments"][i]["tray_id"] = pa_data.calib_datas[i].tray_id;
|
||||||
|
@ -3914,6 +3914,7 @@ int MachineObject::parse_json(std::string payload)
|
||||||
else if ((*it)["n_coef"].is_string())
|
else if ((*it)["n_coef"].is_string())
|
||||||
pa_calib_result.n_coef = stof((*it)["n_coef"].get<std::string>().c_str());
|
pa_calib_result.n_coef = stof((*it)["n_coef"].get<std::string>().c_str());
|
||||||
|
|
||||||
|
if ((*it).contains("confidence"))
|
||||||
pa_calib_result.confidence = (*it)["confidence"].get<int>();
|
pa_calib_result.confidence = (*it)["confidence"].get<int>();
|
||||||
|
|
||||||
pa_calib_results.push_back(pa_calib_result);
|
pa_calib_results.push_back(pa_calib_result);
|
||||||
|
|
|
@ -338,7 +338,7 @@ public:
|
||||||
std::string name;
|
std::string name;
|
||||||
float k_value;
|
float k_value;
|
||||||
float n_coef;
|
float n_coef;
|
||||||
int confidence;
|
int confidence = -1;
|
||||||
};
|
};
|
||||||
|
|
||||||
struct PACalibIndexInfo
|
struct PACalibIndexInfo
|
||||||
|
@ -827,7 +827,7 @@ public:
|
||||||
int command_start_calibration(bool vibration, bool bed_leveling, bool xcam_cali);
|
int command_start_calibration(bool vibration, bool bed_leveling, bool xcam_cali);
|
||||||
|
|
||||||
// PA calibration
|
// PA calibration
|
||||||
int command_start_pa_calibration(const X1CCalibInfos& pa_data, bool is_manual = false);
|
int command_start_pa_calibration(const X1CCalibInfos& pa_data, int mode = 0); // 0: automatic mode; 1: manual mode. default: automatic mode
|
||||||
int command_set_pa_calibration(const std::vector<PACalibResult>& pa_calib_values);
|
int command_set_pa_calibration(const std::vector<PACalibResult>& pa_calib_values);
|
||||||
int command_delete_pa_calibration(const PACalibIndexInfo& pa_calib);
|
int command_delete_pa_calibration(const PACalibIndexInfo& pa_calib);
|
||||||
int command_get_pa_calibration_tab(float nozzle_diameter, const std::string &filament_id = "");
|
int command_get_pa_calibration_tab(float nozzle_diameter, const std::string &filament_id = "");
|
||||||
|
|
|
@ -92,7 +92,7 @@ CalibMode CalibUtils::get_calib_mode_by_name(const std::string &name)
|
||||||
return CalibMode::Calib_None;
|
return CalibMode::Calib_None;
|
||||||
}
|
}
|
||||||
|
|
||||||
void CalibUtils::calib_PA(const X1CCalibInfos &calib_infos, std::string &error_message, bool is_manual)
|
void CalibUtils::calib_PA(const X1CCalibInfos &calib_infos, std::string &error_message, int mode)
|
||||||
{
|
{
|
||||||
DeviceManager *dev = Slic3r::GUI::wxGetApp().getDeviceManager();
|
DeviceManager *dev = Slic3r::GUI::wxGetApp().getDeviceManager();
|
||||||
if (!dev)
|
if (!dev)
|
||||||
|
@ -103,7 +103,7 @@ void CalibUtils::calib_PA(const X1CCalibInfos &calib_infos, std::string &error_m
|
||||||
return;
|
return;
|
||||||
|
|
||||||
if (calib_infos.calib_datas.size() > 0)
|
if (calib_infos.calib_datas.size() > 0)
|
||||||
obj_->command_start_pa_calibration(calib_infos, is_manual);
|
obj_->command_start_pa_calibration(calib_infos, mode);
|
||||||
}
|
}
|
||||||
|
|
||||||
void CalibUtils::emit_get_PA_calib_results(float nozzle_diameter)
|
void CalibUtils::emit_get_PA_calib_results(float nozzle_diameter)
|
||||||
|
|
|
@ -30,7 +30,7 @@ public:
|
||||||
|
|
||||||
static CalibMode get_calib_mode_by_name(const std::string &name);
|
static CalibMode get_calib_mode_by_name(const std::string &name);
|
||||||
|
|
||||||
static void calib_PA(const X1CCalibInfos &calib_infos, std::string &error_message, bool is_manual = false);
|
static void calib_PA(const X1CCalibInfos &calib_infos, std::string &error_message, int mode = 0); // 0: automatic mode; 1: manual mode. default: automatic mode
|
||||||
|
|
||||||
static void emit_get_PA_calib_results(float nozzle_diameter);
|
static void emit_get_PA_calib_results(float nozzle_diameter);
|
||||||
static bool get_PA_calib_results(std::vector<PACalibResult> &pa_calib_results);
|
static bool get_PA_calib_results(std::vector<PACalibResult> &pa_calib_results);
|
||||||
|
|
Loading…
Reference in New Issue